MIL-IBC-1000-EX
Heating jacket for IBC containers in EX design
Ready-to-connect flexible heating jacket with insulation, can be used for temperature maintenance and process-related heating of various substances in a 1000 liter Intermediate Bulk Container (IBC), dimensions 1200 x 1000 x 1160 mm in potentially explosive areas, both in the gas area of zones 1 and 2 and in the dust area of zones 21 and 22. The temperature is controlled via an EX controller/limiter combination in a permanently attached glass-fiber reinforced polyester housing with explosion protection according to ATEX and test certificate.
Note:
Please note that the entire system must be inspected and approved by an expert before commissioning! This article is not an ATEX-certified complete system and is only supplied with type examination certificates for the electrical components used!
Technical data
Nominal voltage | 230 V AC |
Rated power | 2000 W |
Jacket material | electrostatically revulsive PTFE coated fabric |
Heatsealing band | PTFE-insulated resistance element with protective braiding |
Temperature class | T3 to T6 depending on controller/limiter setting |
Temperature control | Safety monitor / limiter |
Temperature range (hold) | 0 up to 100 °C |
Zones | 1+2 (gas) 21+22 (dust) |
Mounting type | Buckles |
Protection class | I |
Protection type | IP 64 |
Mains connection cable | 3,0 m without plug for fixed connection |
Order data
Type | Item no. | |
MIL-IBC-1100- EX | 42002336 |